SYNSTORES - HACCP REPORTING SYSTEM
UNIQUE PROPERTIES OF HW COMPONENTS
- The sensors do not need any power source; they have integrated batteries with a lifetime of at least 10 years.
- The sensors are calibrated and they are certified for contact with foodstuffs.
- The sensors are water- and dust-proof. The sensors‘ surfaces are easy to clean.
- The sensors can be located inside any device – in cooling or freezing display cases and counters, any plug-in freezing systems, drink coolers, freezing and cooling boxes and warehouses.
- The sensors are in round lens shape – they are not an obstacle to any goods manipulation processes.
- Tested by the Czech Office for Standards, Metrology and Testing according to EN 12830:2018.
- Easy installation and replacement, no cables or wires.
- Without any subsequent calibrations.
HW COMPONENTS - TECHNICAL PARAMETERS
Gateway GB41
LTE gateway for wireless temperature
sensors and open-door sensors
External 5V USB adapter
Operating temperature: -10˚C to 50˚C
Storage temperature: -40˚C to 55˚C
GSM LTE
Integrated SIM
Integrated GSM antenna
2 GB internal memory, at least 100,000 samples
Backup battery for at least 24 hours of operation
Dimensions 210 x 210 x 80 mm
IP20 protection
HACCP temperature sensor TS1
Fully wireless temperature sensor
Temperature measurement accuracy of 0.3°C
within the temperature range between -30°C and +50°C for the period of at least 10 years
Applicable temperature range of the temperature sensor between -30°C and +50°C Measuring interval of 2 minutes
Applied frequency – 868.3 MHz
Battery minimum lifetime of 10 years, integrated battery
Open-space range of 800 m
Dimensions 80 x 20 mm, round
No calibrations needed
IP65 protection
Temperature and humidity sensor - Lobby sensor LS1
Fully wireless temperature and humidity sensor in the store
Temperature measurement accuracy of 0.5°C
Applicable temperature range of the temperature sensor between -5°C and +45°C
Humidity measurement 0-100%
Humidity measurement accurancy +- 3% RH within range 0-80% RH
Measuring interval of 2 minutes
Applied frequency – 868.3 MHz
Open-space range of 400 m
Dimensions 80 x 80 x 12 mm
Replaceable battery CR2032, lifetime up to 10 years
IP20 protection
NEW TYPES OF SENSORS
Base unit for 2 external sensors EB2
Fully wireless unit
Operating temperature: -30 °C to +50 °C
Measuring interval of 2 minutes
Applied frequency – 868.3 MHz
Battery minimum lifetime of 10 years, integrated battery, replaceable
Open-space range of 800 m
Dimensions 80 x 80x 25 mm
Possible to connect up to 2 sensors
Mounting by magnets
No calibrations needed
IP65 protection
Penetration sensor for core temperature (1.5 m cable) NS4
Temperature measurement accuracy of 0.4°C
within the temperature range between -30 °C
and +80 °C for the period of at least 10 years
No calibrations needed
Cable length 1.5 m
IP65 protection
External sensor 50 mm tip (1.5 m cable) ES5
Temperature measurement accuracy of 0.4°C
within the temperature range between -30 °C
and +80 °C for the period of at least 10 years
No calibrations needed
Cable length 1.5 m
IP65 protection
Product temperature simulation sensor (1.5 m cable) PS7
Temperature measurement accuracy of 0.4°C
within the temperature range between -30 °C
and +50 °C for the period of at least 10 years
No calibrations needed
Cable length 1.5 m
IP65 protection
CO2 sensor SCO2
NDIR CO2 sensor technology
Dual-channel detection for superior stability
Measurement range: 400 ppm – 10.000 ppm
Accuracy: ±(30 ppm + 3%)
Accuracy drift over lifetime: ± 50 ppm
Humidity measurement: ± 5 %RH (25°C, 0 – 95 %RH) - indicative measurement
Supply 12V DC (Adapter 230V AC/12V DC included)
Measuring interval: 5 minutes
Consumption 0.1W
Dimensions 80 x 80 x 12 mm
IP20 protection
Service-TAG ST1
Identifies automatically the Service Technician when working in the store on a service call and reports this to store manager and records it in the SYNSTORES application.
Dimensions: diameter 50mm
Used transmition frequencies: 868MHz
Range: 800m (open space)
Power supply: Lithium battery, lifespan of 10 years, integrated
Identification: unique TAG number
Protection rating: IP65
Broadcast reception: only via SYNSTORES GATEWAY
Material: ABS
ENERGY MONITORING UNIT
Energy Monitoring Unit 400V EMU3
Power supply: 3x 400V AC
Calibration: Calibration from production
Measurements: Electricity consumption
Range of measurement: max. 3 x 16A (max. 3 x 32A)
Measuring accuracy: 2%
Measuring interval: 5 minutes
Used trasmission frequency: 868,3 MHz
Reach: 500 m
Operating conditions: -30 °C / +60 °C
Dimensions: 230 x 220 x 95 mm
Insulation class: IP40
Sensor type: Wattmetr
Material: ABS
Assembly/installation: By connecting to electric outlets, freely or via a mounting tape
Energy Monitoring Unit 230V EMU1 / EMU1S
Power supply: 230V AC
Calibration: Calibration from production
Measurements: Electricity consumption in kWh / 230S actuating
Range of measurement: 0–16A
Measuring accuracy: 2%
Measuring interval: 5 minutes
Used trasmission frequency: 868,3 MHz
Reach: 500 m
Operating conditions: -30 °C / +60 °C, c 0–95 %
Dimensions: 140 x 80 x 40 mm
Insulation class: IP40
Sensor type: Wattmetr
Material: ABS
Assembly/installation: By connecting to electric outlets, freely or via a mounting tape
IQC31 measuring and control system
Power supply: 24 DC
Consumption. 80 mA (without load)
Insulation class: IP40
Ambient working temperature: -30 °C / +60 °C
Maximum humidity: < 95% non-condensing
Operating conditions: -30 °C / +60 °C, humidity 0–95 %
Dimensions: 110 x 90 x 60 mm (6U)
Weight: 0,100 kg
Assembly: DIN rail
POSSIBLE SENSOR COMBINATIONS
ACCESSORIES
MONITORING, DIGITAL HACCP, REPORTING AND MUCH MORE
- overview
- reports
- events
- alarms
- summary
- consumption (graphs, sheets)
- store performance comparison - and evaluation
- equipment performance comparison
- open / closed doors statistics and evaluation
- service TAG (technician on store)
- service call button
- critical issue button
REPORTS, ALERTS
You can set up e-mail alerts with corrective action prompt, temperature alarms, and regular sending of reports.ARCHIVING
A complete HACCP report in pdf format can be downloaded from the application for the selected date at any time.Example report ...